Prensip of ölçüm AC gerilim aralık ile a multimetre

 

VD1 ve VD2 in the circuit are the redresör diyotlar inside the meter. As the meter head can only flow direct current, when measureing AC voltage, the AC current needs to be converted into direct current. This is achieveed by a redresör circuit composed of two diodes. C1 is the DC isolation capacitor inside the meter, hang prevents the direct current in the external circuit from flowing through the meter head to prevent the direct current in the external circuit from affecting the measurement results of AC voltage, Us is the AC voltage in the external circuit to be measured.


The AC gerilim in the external circuit is added to the redresör devre through C1, converting the AC current (üretilen by the AC voltaj) into DC current. This DC current meter tip causes the pointer to deflect, only the AC voltage value.


İlgili ölçüm prensip of AC gerilim aralık, the takip noktalar olmalı ayrıca açıklanmalıdır.

1. Ne zaman ölçüm AC voltaj% 2c kırmızı ve siyah metre çubuklar bağlı bağlı paralel paralel ölçülen voltaj kaynak dış devre% 2c hangisi çok uygun için çalışır.


2. Her ne kadar AC gerilim is ölçülen, the DC akım akış içinden doğrultucu devre in the meter head.


3. Ne zaman ölçüm AC gerilim, the pil in the meter is not powered, and the current that causes the pointer to deflect is provided by the AC voltage source in the circuit under test. Due to the large step-down resistance in the meter (not shown in the figure), the impact of measurement on the voltage source under test is also very small.


4. Ne zaman orada yok gerilim içinde test devre, orada yok akım akıyor içinden metre kafa, the pointer saptıramaz saptıramaz, ve the voltaj indication is zero. At the same range, the high the voltage in the external circuit, the greater the DC current flow through the meter after rectification, the greater the deflection angle of the pointer, and the greater the gösterge gösterilmiş voltaj değer.


5. Due to the fact that the battery inside the meter is not used for measureing AC voltage, the voltage of the battery inside the meter does not affect the measurement of AC voltage.


6. Ne zaman ölçüm AC gerilim, orada olmalı olmalı a güç kaynak içinde dış devre, so the harici devre olmalı ayrıca be enerjili sırasında ölçüm.


7. Due to the constantly changing direction of AC current, and the AC voltage range of the pointer multimeter is only used to measure 50Hz AC power, the positive and negative half cycle amplitudes of this AC power are symmetrical. Therefore, the AC voltage sent into the meter needs to pass through a rectification circuit, so that the direction of the current flowing through the meter head is determined. In this way, when measuring AC voltage, the red and black meter bars have no polarity and can be interchanged, unlike measuring DC voltage or DC current.


8. AC voltaj aralık gösterge kadran işaretleyici multimetre tasarlanmış 50Hz sinüs dalga AC güç. Bu nedenle, ne zaman ölçen olmayan 50Hz sinüs gerilim veya diğer frekans ^ sinüs gerilim, eğer ölçülen gerilim yanlış, onlar olabilir ölçülebilir kullanılabilen a dijital multimetre.


9. AC gerilim gösterge ölçek hesaplanmış bazlı on etkin değer in sinüs dalga gerilim.,

 